UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 41380

12.X/13.1 Virtex-5 - When using a PMCD the following error is seen: ERROR:PhysDesignRules:2405

Description

When implementing a design in ISE 12.X/13.1, I receive the following error:

ERROR:PhysDesignRules:2405 - The calculated frequency value, 1000.000000, of the
   CLKIN1_PERIOD attribute on the PLL_ADV(PMCD) instance PMCD_1 is
   outside the allowed range of 1.000000 - 645.000000 MHz. Please change the
   CLKIN1_PERIOD attribute value in order to be within the allowed range for
   this device.
ERROR:Pack:1642 - Errors in physical DRC.


Solution

The reason for this error is that when a PMCD is used in a Virtex-5 design the tools automatically re-target the PMCD to a PLL.

Because the PMCD does not have a CLKIN_PERIOD attribute the default value of 1 nS is used.

This results in the tools assuming that the PLL is being run at 1Ghz which is outside the specifications.

 

This problem is fixed in ISE Design Suite 13.2. 

ISE 12.x can still be used as this was only a warning and not an error in those versions.


AR# 41380
Date Created 03/22/2011
Last Updated 12/01/2014
Status Active
Type General Article
Tools
  • ISE Design Suite - 13.1