AR# 41965 MIG v3.7 Virtex-6 DDR2/DDR3 - HAMMER data pattern does not work in simulation

The MIG Traffic Generator does not simulate the HAMMER data pattern correctly. Why is app_wdf_data always undriven by the traffic generator even when I set DATA_PATTERN=DGEN_HAMMER in sim_tb_top.v?
This is a problem with the HAMMER pattern process inside v6_data_gen.v and only affects the Verilog design. Please replace v6_data_gen.v with the modified version provided below to resolve the problem.

v6_data_gen.v

This will be fixed with the release of ISE 13.2 software and MIG v3.8.

Master Answer Records

Answer Number Answer Title Version Found Version Resolved
41918 MIG v3.7-v3.8 Virtex-6 DDR2/DDR3 - Traffic Generator does not simulate other data or command patterns N/A N/A

Associated Answer Records

Answer Number Answer Title Version Found Version Resolved
41918 MIG v3.7-v3.8 Virtex-6 DDR2/DDR3 - Traffic Generator does not simulate other data or command patterns N/A N/A
39128 MIG Virtex-6 and Spartan-6 v3.7 - Release Notes and Known Issues for ISE Design Suite 13.1 N/A N/A
AR# 41965
Date Created 05/16/2011
Last Updated 05/20/2012
Status Active
Type Known Issues
Devices
  • Virtex-6 HXT
  • Virtex-6 LX
  • Virtex-6 LXT
  • Virtex-6 SXT
IP
  • MIG
Feed Back