AR# 42089 LogiCORE IP Tri-Mode Ethernet MAC v5.1 and Earlier - "ERROR:NgdBuild:973" - The Temac Symbol Is Not Supported

When implementing a designwith LogiCORE IP Tri-Mode Ethernet MAC v5.1 and earlier, the following error message displays:

"ERROR:NgdBuild:973 - The temac symbol 'trimac_locallink/trimac_block/trimac_core' is not supported in the spartan6."

The issue occurs when the core is named 'temac' or 'temac_single' during the generation of the core in Core Generator.This is because there is already a Xilinx primitive with those names.

The error goes away if the core is re-generated with a different name. In future releases of the LogiCORE IP Tri-Mode Ethernet MAC, users will not be allowed to generate a core with these names.