We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 4233

F1.4 Simulator: Deletes Formulae when "Simulate Single Component" option is selected


Keywords: simulate, formulas, lost, removed

Urgency: Standard

General Description:

One option for applying stimuli to signals when using the
Foundation Logic Simulator is to assign custom made
formulae to the signals.
The formulae get saved in a <design_name>.frm file
and can be used in subsequent simulations.
However, these formulae only get saved when the whole
design is simulated.
If the File->Simulate Single Component option is chosen
and formulae applied, on closing the simulation window,
the formulae are lost.


A workaround is to create your own text file in which to store the formulae.

The text entered into the "Set formulas" window can be cut and paste into this text file
and pasted back again on subsequent simulations of that component.

This is fixed in F1.5
AR# 4233
Date Created 07/13/1998
Last Updated 04/04/2000
Status Archive
Type General Article