PlanAhead - I cannot find the recovery or removal data of an asynchronous Flip-Flop from report_timing


I am trying to analyze the recovery and removal timing for an FDC flop (asynchronous clear), but cannot find the information or the commands to generate that data.


A comprehensive report should iterate through all path groups (including the async defaults) and report the worst violations.

You can report the specific group timing with the group filter:

% report_timing -group **async_default**