13.2 Project Navigator - Using Smartguide causes Implementation to fail in two cases fails with spaces in project path

Description

The following two situations cause the Implementation (MAP or Place & Route process (PAR)) to fail when using Smartguide.

1.The smartguide option passed to map uses a relative path for the smartguide file. This can cause a problem if SmartXplorer is also being used because the SX runs are done from different directories.

2. The smartguide option passed to PAR does not quote the path, so it fails if it has spaces in it.

Solution

These issues will be addressed in ISE Design Suite 13.3.