UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 43059

LogiCORE IP Ethernet 1000BASE-X PCS/PMA or SGMII v11.1 - Error - Invalid Target Device when Running Virtex-7 Example Design in 13.2 and Later

Description

When the LogiCORE 1000BASE-X PCS/PMA or SGMII v11.1 is generated for Virtex-7, the example design UCFtargets an xc7v285tffg784-1 device.Because this device is no longer a valid part, the tools will error out if the example design implementation script is run in ISE Design Suite 13.2 software or later.

Solution

The example_design/<core_name>_example_design.ucf can be modified to target one of the Virtex-7 devices available in the latest software.For example, at the top of theUCF, the target part can be changed to:

CONFIG PART = xc7v585t-ffg1761-1;

When using the1000BASE-X or SGMII core, the target part listed above is the only change needed. However, it is recommended that the following location constraints be removed as well:

INST "receive_gmii_tx_clk" LOC = "BUFIO_X0Y3" ;
NET "gmii_tx_clk_bufio" TNM_NET = "TN_gmii_tx_clk_bufio" ;
TIMEGRP "TN_gmii_tx_clk_bufio" AREA_GROUP = "CLKAG_gmii_tx_clk_bufio" ;
AREA_GROUP "CLKAG_gmii_tx_clk_bufio" RANGE = CLOCKREGION_X0Y0;

INST "drive_tx_clk" LOC = "BUFR_X0Y2" ;
NET "gmii_tx_clk_bufr" TNM_NET = "TN_gmii_tx_clk_bufr" ;
TIMEGRP "TN_gmii_tx_clk_bufr" AREA_GROUP = "CLKAG_gmii_tx_clk_bufr" ;
AREA_GROUP "CLKAG_gmii_tx_clk_bufr" RANGE = CLOCKREGION_X0Y0