AR# 44300

LogiCORE IP Serial RapidIO Gen2 v1.2 - Link Requests (LREQ) not sent before going into the Fatal Error State


When generatingLogiCORE IP Serial RapidIO Gen2 v1.2, I selected a value in 'Additional Link Requests Before Fatal' field of the CORE GeneratorGUI. However, in my design the core does notsend the requested number of Link Requests (LREQ) before going into the Fatal ErrorState.


This is a known issue. It will be fixed in the future release of the core.

Revision History:
10/26/2011 - Initial Release

AR# 44300
Date Created 10/13/2011
Last Updated 05/19/2012
Status Archive
Type Known Issues
  • Serial RapidIO