AR# 44701

13.3 XST - What is new in XST 13.3?

Description

What is new in 13.3 XST software?

Solution

XST includes the following Strict RTL checks for 13.3:

(Xilinx Answer 44499) - XST - Severity Change for XST message "WARNING:HDLCompiler:1128" Beginning ISE 13.3 Software
(Xilinx Answer 44500) - XST - Multiple dimension in gate instantiation in RTL code causes "ERROR:HDLCompiler:1821" beginning ISE 13.3 software
(Xilinx Answer 43994) - XST - Severity Change for XST message "WARNING:HDLCompiler:532" beginning ISE 13.3 software
(Xilinx Answer 44530) - 13.3 XST - "ERROR:HDLCompiler:1818 - "< * >.v" Line < * >: Invalid size of integer constant literal"
(Xilinx Answer 44507) - 13.3 XST - "ERROR:HDLCompiler:1828 - "< * >.v" Line < * >: Translate_on found outside a translate_off block"
(Xilinx Answer 44506) - 13.3 XST - ERROR:HDLCompiler:1832 - "< * >.v" Line < * >: Negative shift distance
(Xilinx Answer 44505) - 13.3 XST - "ERROR:HDLCompiler:1831 - "< * >.v" Line < * >: Complex expression in event control"
(Xilinx Answer 44597) - 13.3 XST - "ERROR:HDLCompiler:1830 - "< * >.v" Line 5: Cannot omit port direction for function/task declarations"
(Xilinx Answer 44598) - 13.3 XST - ERROR:HDLCompiler:114 - "< * >.v" Line 10: /* in comment
(Xilinx Answer 44595) - 13.3 XST - ERROR:HDLCompiler:860 - "top.v" Line 1: Unknown nettype non ignored
(Xilinx Answer 44558) - XST - Severity Change for XST message " WARNING:HDLCompiler:1330" Beginning with ISE 13.3 Software
(Xilinx Answer 44556) - XST - Severity Change for XST message "WARNING:HDLCompiler:922" Beginning ISE 13.3 Software
(Xilinx Answer 44557) - XST - Severity Change for XST message " WARNING:HDLCompiler:597" beginning ISE 13.3 software
(Xilinx Answer 44554) - XST - "ERROR:HDLCompiler:711 - "< * >.v" Line 11: Found more than one declaration of port"
(Xilinx Answer 44536) - XST - Severity Change for XST Message "WARNING:HDLCompiler:226" Beginning with ISE 13.3 Software
(Xilinx Answer 44539) - XST - Severity Change for XST message "WARNING:HDLCompiler:690" Beginning with ISE 13.3 Software
(Xilinx Answer 44522) - XST - "ERROR:HDLCompiler:1824 only trireg nets can have a charge strength specification" Beginning in ISE 13.3 Software
(Xilinx Answer 44523) - XST - Severity Change for XST message "WARNING:HDLCompiler:1419" beginning in ISE 13.3 Software
(Xilinx Answer 44521) - XST - Severity Change for XST message "WARNING:HDLCompiler:1511" Beginning in ISE 13.3 Software