We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 45942

14.x Timing - Unable to remove path from PAD to BUFPLL unconstraint section


I attempted to remove a path from PAD to BUFPLL from the Unconstraint section of the Timing Report; I applied a TPSYNC constraint on the BUFPLL component. This additional constraint was ignored and the path is still "Unconstrained."

How do I remove this path from the Unconstrained Path Report?


The full clock path must be placed in the FROM:TO statement to remove it from the Unconstrained Path Report.

AR# 45942
Date Created 11/12/2012
Last Updated 01/17/2013
Status Active
Type General Article
  • ISE Design Suite - 13.4
  • ISE Design Suite - 13.1
  • ISE Design Suite - 13.2
  • More
  • ISE Design Suite - 13.3
  • ISE Design Suite - 14.1
  • ISE Design Suite - 14.2
  • ISE Design Suite - 14.3
  • ISE Design Suite - 14.4
  • Less