AR# 47385 MIG 7 Series RLDRAMII - Timing violations may occur when Debug Signals feature is enabled

Version Found: v1.5
Version Resolved and other Known Issues: See (Xilinx Answer 45195).

When implementing the MIG 7 Series RLDRAMII design with the Debug Signals feature enabled, timing violations may be seen.

Example Timing Errors:
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
109037 paths analyzed, 22057 endpoints analyzed, 74 failing endpoints
74 timing errors detected. (74 setup errors, 0 hold errors, 0 component switching limit errors)
Minimum period is 4.749ns.
--------------------------------------------------------------------------------
Slack (setup path): -0.305ns (requirement - (data path - clock path skew + uncertainty))
Source: u_mig_7series_v1_4/u_rld_memc_ui_top_std/gen_ui_fifos.u_rld_ui_top/u_usr_wr/gen_wdf0[0].u_wdf_data0/FIFO36E1 (RAM)
Destination: u_traffic_gen_top/u_memc_traffic_gen/memc_control/addr_r_19 (FF)
Requirement: 4.444ns
Data Path Delay: 4.307ns (Levels of Logic = 4)
Clock Path Skew: -0.374ns (1.256 - 1.630)
Source Clock: clk rising at 0.000ns
Destination Clock: clk rising at 4.444ns
Clock Uncertainty: 0.068ns


These timing errors do not occur when the Debug Signals feature is not enabled. To temporarily work around this issue, disable the Debug Signals and rerun implementation.
AR# 47385
Date Created 04/23/2012
Last Updated 04/23/2012
Status Active
Type
Devices
  • Artix-7
  • Kintex-7
  • Virtex-7
  • Virtex-7 HT
IP
  • MIG 7 Series
Feed Back