AR# 47452

LogiCORE IP Video Scaler v6.00.a (Vivado 2012.1) - Why are my outputs always driven to zero when using Vivado Synthesis?

Description

Why are my outputs always driven to zero when using Vivado Synthesis?

Solution

This is a known issue in the Video Scaler v6.00.a when generated from Vivado Design Suite 2012.1.

This issue can be worked around by changing the project synthesis options in Vivado to XST.

  • Select the "Synthesis Settings" link on the left hand side of the Vivado GUI and choose "XST Default" from the drop-down menu.

This issue is fixed in Vivado Design Suite 2012.2.

Please see (Xilinx Answer 31958) for a detailed list of LogiCORE IP Video Scaler Release Notes and Known Issues.

Linked Answer Records

Master Answer Records

Answer Number Answer Title Version Found Version Resolved
31958 LogiCORE IP Video Scaler - Release Notes and Known Issues N/A N/A

Associated Answer Records

Answer Number Answer Title Version Found Version Resolved
31958 LogiCORE IP Video Scaler - Release Notes and Known Issues N/A N/A