We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 50109

14.1 Project Naviagtor - Not possible to run XST is a separate working directory: ERROR:HDLCompiler:0 - "Unknown" Line 0: The path "../../../P15xf_test" does not exist


With ISE 14.1 design tools, it is not possible to set the XST working directory outside of the project directory. The following occurs if this is done:

ERROR:HDLCompiler:0 - "Unknown" Line 0: The path "../../../P15xf_test" does not exist


This issue does not occur in ISE 14.2 design tools.

For ISE 14.1 design tools, use the default location (project directory) for the XST directory.
AR# 50109
Date Created 05/23/2012
Last Updated 04/05/2013
Status Active
Type Known Issues
  • ISE Design Suite - 14.1