UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 50599

Vivado HLS - RTL implementation of the design results in XST reporting "ERROR:Portability:3 - This Xilinx application has run out of memory or has encountered a memory conflict"

Description

RTL implementation of the design results in XST reporting "ERROR:Portability:3 - This Xilinx application has run out of memory or has encountered a memory conflict"

Solution

To work around this issue, disable the-fsm_extract option in XST.

Alternatively, it may be possible to work around this issue by reducing the number of inline directives by removing the -recursive options in the design.
AR# 50599
Date Created 07/23/2012
Last Updated 10/05/2012
Status Active
Type Known Issues
Tools
  • AutoESL
  • AutoESL - 2011.4.2
  • AutoESL - 2011.4
  • More
  • AutoESL - 2012.1
  • Vivado
  • Less