UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 52147

MIG 7 Series DDR3 - tRFC and tRAS simulation errors occur during calibration when running at or below 400 MHz

Description

Version Found: MIG 7 Series v1.7
Version Resolved: See (Xilinx Answer 45195)

If simulating a MIG 7 Series FPGA DDR3 design running at or below 400 MHz, tRFC and tRAS max violations can occur before calibration completes that are similar to the following:

"# sim_tb_top.mem_rnk[0].mem.gen_mem[0].*.cmd_task: at time 112279326.0 ps ERROR: tRFC maximum violation during No Op # sim_tb_top.\mem_rnk[0].gen_mem[0].*.chk_err: at time 134531257.0 ps
ERROR: tRAS maximum violation during Precharge to bank 0 "

These violations appear before calibration is completed.

Solution

The violations occur due to a wait period during the DQS_FOUND stage of calibration and can be safely ignored.

Revision History
10/16/2012 - Initial release

AR# 52147
Date Created 10/02/2012