AR# 52176 MIG 7 Series DDR3 - 48-bit design unable to fit into 2 HP banks

Version Found: MIG 7 Series v1.6
Version Resolved: See (Xilinx Answer 45195)

When targeting a 48-bit DDR3 interface it is possible to fit this into 2 HP banks. However, when targeting the xc7k70t the MIG 7 Series Bank Selection page prevents the interface from being placed into 2 HP banks while retargeting to a larger part allows this configuration.

To work around this issue, generate a MIG 7 Series design targeting the larger device with the same package type, then generate a MIG 7 series design targeting the xc7k70t using Fixed Pin Out mode in the interface, and import the UCF pinout from the larger device.

Revision History
10/16/2012 - Initial release

AR# 52176
Date Created 10/03/2012
Last Updated 10/16/2012
Status Active
Type Known Issues
Devices
  • Kintex-7
IP
  • MIG 7 Series
Feed Back