AR# 52496

14.2 PlanAhead - An internal exception occurs when the "Implementation Settings" are accessed from the Design Flow pane


An internal exception occurs and the menu settings are not displayed when I attempt to open the "Implementation Settings" from the left-side in the Design Flow pane.

This report is an indication that an internal PlanAhead error occurred. This information is useful for debugging. 
 Please open a case with Xilinx Technical Support with this file and a test case attached.
 at ui.views.d.m.n.aKq(SourceFile:35)
 at ui.frmwork.a.dHp(SourceFile:55)
 at ui.c.w.a.n.dCS(SourceFile:204)
 at ui..c.w.a.n.a(SourceFile:431)
 at ui..c.w.a.k.btC(SourceFile:167)


This issue has been reported under Unix machines only and has been resolved in the PlanAhead 14.3 tool.

This problem prevents the "Implementation Settings" menu from showing up.

To work around this issue, go to the "Design Runs" tab and select the "Implementation" run. Then, just above the panel on the left side, there is a box which shows the "Properties" of the selected object. From there, it is also possible to setup the "Implementation Options".