AR# 53060 ZC702 Evaluation Board for the Zynq-7000 XC7Z020 AP SoC User Guide v1.0 (UG850) - SiT9102 Oscillator frequency stability incorrect


The ZC702 Evaluation Board for the Zynq-7000 XC7Z020 AP SoC User Guide v1.0 (UG850), lists the PPM frequency jitter as 20 ppm.

However, the data sheet for the SiT9102AI-243N25E200.00000 oscillator, described in UG850, lists a frequency stability of 50 ppm.

Which value is correct?


The data sheet for the SiT9102AI-243N25E200.00000 is correct; the PPM frequency jitter for the SiT9102 device used on the ZC702 Evaluation Board is 50 ppm.

The ZC702 Evaluation Board for the Zynq-7000 XC7Z020 AP SoC User Guide v1.1 (UG850) has been updated with the correct frequency stability figure.
AR# 53060
Date Created 11/26/2012
Last Updated 11/26/2012
Status Active
Type
Feed Back