We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 53134

7 series - Can CFGBVS be connected by a pull-up resistor?


During board layout, CFGBVS was accidentially connected to Vcco_0 with a pull-up resistor rather than connected directly as recommended in the 7 Series Configuration User Guide.

Is this an issue?


CFGBVS only requires that the pin reach the expected signal switching level relative to Vcco_0.

1k or stronger is expected to be fine.

AR# 53134
Date Created 11/27/2012
Last Updated 03/05/2013
Status Active
Type General Article
  • Kintex-7
  • Artix-7
  • Virtex-7