AR# 55531

Design Advisory for MIG 7 Series v1.9 DDR3/DDR2 - PRBS Calibration results are not applied (RTL Update Required)


Version Found: MIG 7 Series v1.9
Version Resolved: See (Xilinx Answer 54025)

The MIG 7 Series DDR3/DDR2 design performs Read Leveling Calibration followed by PRBS Read Leveling Calibration to fine tune the centering of the read capture clock. In the MIG 7 Series v1.9 rtl ONLY, a specific line of code is incorrectly commented out causing the results of the PRBS Read Leveling Calibration stage (increments and decrements to the Phaser_IN blocks) to not be applied as if the stage of calibration did not run. Calibration will not fail, but the fine tuned adjustments found during PRBS Read Leveling will not be applied. This can cause read data errors post calibration. Manual modification is required within the MIG 7 Series v1.9 rtl.

This issue is resolved in MIG 7 Series v2.0. Therefore, only MIG 7 Series v1.9 requires this update.


To work around this issue, perform the following:

Standard MIG 7 Series Coregen IP:

  1. Locate line 228 within the "user_design/rtl/phy/mig_7series_v1_9_ddr_phy_prbs_rdlvl.v" module:
         //assign pi_stg2_prbs_rdlvl_cnt = prbs_dqs_cnt_r;
  2. Uncomment this statement:
        assign pi_stg2_prbs_rdlvl_cnt = prbs_dqs_cnt_r;
  3. Generate the bitstream again with this rtl change.

Note for Vivado Users: If using the "Open IP Example Design" feature to generate a Vivado project with the MIG Example Design, the MIG rtl is not copied from the local project directory but rather from the Vivado tool tree.  If the update was made to the local project mig_7series_v1_9_ddr_phy_prbs_rdlvl.v file, it will not be reflected in the example design Vivado project.  The update must be manually made in the example design Vivado project.

EDK MIG 7 Series IP:

The Standard MIG 7 Series Coregen IP flow can be used to update the rtl in the local MIG design. However, if the example design is open, the change is not reflected. The update noted in the Standard MIG 7 Series Coregen IP section can be made to either:

  • The Vivado Tree: C:\Xilinx\Vivado\2013.1\ids_lite\ISE\coregen\ip\xilinx\other\com\xilinx\ip\mig_7series_v1_9\data\dlib\7series\ddr3_sdram\verilog\rtl\phy\mig_7series_v1_9_ddr_phy_prbs_rdlvl.v
  • The local Example Design: "example_project/mig_7series_0_example/mig_7series_0_example.srcs/sources_1/ip/mig_7series_0/mig_7series_0/user_design/rtl/phy/mig_7series_v1_9_ddr_phy_prbs_rdlvl.v"

When using the AXI MIG 7 Series IP, axi_7series_ddrx_v1_08_a, the location of the required update is:
Vivado Tree: C:\Xilinx\Vivado\2013.1\ids_lite\EDK\hw\XilinxProcessorIPLib\pcores\axi_7series_ddrx_v1_08_a\hdl\verilog\mig_7series_v1_9_ddr_phy_prbs_rdlvl.v

Revision History
05/03/13 - Included EDK MIG 7 Series IP section
04/15/13 - Initial release

Linked Answer Records

Master Answer Records

Associated Answer Records

Answer Number Answer Title Version Found Version Resolved
55891 Kintex-7 FPGA Embedded Kit - MIG 7 Series v1.9 DDR3/DDR2 PRBS Calibration results are not applied N/A N/A
AR# 55531
Date Created 04/12/2013
Last Updated 07/02/2013
Status Active
Type Design Advisory
  • Artix-7
  • Kintex-7
  • Virtex-7
  • Vivado Design Suite - 2013.1
  • ISE Design Suite - 14.5
  • MIG 7 Series