14.x System Generator - "Internal Error - Stride/length conversion"

Description

If I attempt to generate a netlist for a design in 14.x System Generator, the following error occurs:

*** ERROR ***
Errors occurred during netlist generation.
Internal Error - stride/length conversion

The error does not occur for all designs.

What is wrong? How do I resolve this issue?

Solution

The error occurs when Create interface document is checked in the SysGen token.

To work around this issue, uncheck this box in the SysGen token. Or, if possible, use Vivado System Generator.