AR# 56229

MIG 7 Series RLDRAM II / 3 - Timing failures can be seen in the MIG generated example for multi-controller designs when the Debug Port is enabled

Description

Version Found: v1.9.a
Version Resolved: See (Xilinx Answer 54025)

For MIG 7 series RLDRAM multi-controller designs, it is possible for the following paths to fail timing in the MIG generated Example Design when the Debug Port is enabled:

From:

u_my_mig/c1_u_rld_memc_ui_top_std/u_rld_phy_top/u_qdr_rld_phy_read_top/
u_qdr_rld_phy_read_stage2_cal/cal_done_reg/C

To:

CHIPSCOPE_INST.u_ila_rldx/inst/ila_core_inst/shifted_data_in_reg[6][527]_srl7/D

From

c1_u_traffic_gen_top/u_memc_traffic_gen/tg_status/error_set_reg/C

To:

CHIPSCOPE_INST.u_ila_rldx/inst/ila_core_inst/shifted_data_in_reg[6][1]_srl7/D

Solution

If you see these timing failures, the following code changes can be made in example_top.v/ to resolve them:

Change:

    (*mark_debug = "TRUE" *) wire         c0_dbg_tg_compare_error;  

   (*mark_debug = "TRUE" *) wire          c0_dbg_init_calib_complete;

  assign init_calib_complete = c0_init_calib_complete & c1_init_calib_complete;

  assign tg_compare_error = c0_tg_compare_error | c1_tg_compare_error;

  assign c0_dbg_tg_compare_error = tg_compare_error;

 assign c0_dbg_init_calib_complete = init_calib_complete;

    .PROBE1 (c0_dbg_tg_compare_error),  

    .PROBE97(c0_dbg_init_calib_complete )

To (please see the changes in bold):

  //  (*mark_debug  = "TRUE" *) wire          c0_dbg_tg_compare_error;  

  //  (*mark_debug  = "TRUE" *) wire          c0_dbg_init_calib_complete;

  assign init_calib_complete = c0_init_calib_complete & c1_init_calib_complete;

  assign tg_compare_error = c0_tg_compare_error | c1_tg_compare_error;

  // assign c0_dbg_tg_compare_error = tg_compare_error;

  // assign c0_dbg_init_calib_complete = init_calib_complete;

    .PROBE1 (c0_tg_compare_error ),  

    .PROBE97(c0_init_calib_complete )

Revision History
07/18/2013 - Initial release

Linked Answer Records

Master Answer Records

Answer Number Answer Title Version Found Version Resolved
54025 MIG 7 Series - IP Release Notes and Known Issues for Vivado 2013.1 and newer tool versions N/A N/A
AR# 56229
Date Created 06/04/2013
Last Updated 07/21/2015
Status Active
Type Known Issues
Devices
  • Artix-7
  • Kintex-7
  • Virtex-7
IP
  • MIG 7 Series