AR# 56660

LogiCORE IP Serial RapidIO Gen2 v2.0 - SRIO Gen2 v2.0 Rev2 Patch


This answer record contains the SRIO Gen2 v2.0 Rev2 patch. The patch incorporates fixes for the following two issues in addition to the fixes provided in the Rev1 patch, see (Xilinx Answer 55737).

  • Added support for behavioral simulation using NCSIM
  • Corrected patch version read issue when reading CAR register at offset of 0x0004

For LogiCORE IP Serial RapidIO Gen2 v2.0 release notes, see (Xilinx Answer 54648).


Please download the SRIO Gen2 v2.0 Rev2 patch files (srio_gen2_v2_0rev2.zip) provided at the end of this answer record.

Follow these steps to install the patch:

  1. Prior to installing this update, the Serial RapidIO Endpoint Gen2 v2.0 (available in Vivado 2013.2) must be installed.
  2. Unzip the srio_gen2_v2_0rev2.zip archive to the directory you choose.
  3. Open up Vivado 2013.2 tool release and create a new project.
  4. Open up IP catalog. Right click on the Serial RapidIO GEN2 core and choose IP Settings
  5. Click Add Repositories and point it to the location where you have unzipped the patch from step 2 above.
  6. Click OK and youre now ready to generate the core.

If you have previously generated the core, you can choose Upgrade IP on your existing SRIO GEN2 core.

Alternatively, you could use the MYVIVADO environment variable and point this to the location of the patch.

Revision History
07/05/2013 - Initial release
07/25/2013 - Updated patch installation instructions and readme file


Associated Attachments

Name File Size File Type
srio_gen2_v2_0rev2.zip 3 MB ZIP

Linked Answer Records

Master Answer Records

Answer Number Answer Title Version Found Version Resolved
54648 LogiCORE IP Serial RapidIO Gen2 Core - Release Notes and Known Issues for Vivado 2013.1 and newer tools N/A N/A
AR# 56660
Date Created 07/02/2013
Last Updated 11/05/2013
Status Active
Type Known Issues
  • Vivado Design Suite - 2013.2
  • Serial RapidIO