AR# 57265

2013.2 AXI Interconnect - [Common 17-55] 'get_property' expects at least one object. [axi_clock_converter_0_clocks.xdc":18]

Description

When using an AXI Interconnect or AXI clock converter, the following Critical Warnings occur:

[Common 17-55] 'get_property' expects at least one object. [axi_clock_converter_0_clocks.xdc":18]
[Designutils 20-964] Command failed: can't read "min_clk": no such variable. [axi_clock_converter_0_clocks.xdc":19]

How do I resolve these?

Solution

These warnings occur when a clock constraint has not been created for which the clock_converter block can generate its cross-clock constraints relative to. To fix the issue, be sure to add a create_clock constraint for all input clocks to the AXI Interconnect or clock converter.