UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 57304

Vivado Timing - Where can I find the Fmax of a clock signal in the timing report?

Description

Where can I find the Fmax of a clock signal in the timing report?

Solution

The Fmax value of a clock signal is not explicitly given in the report_timing/report_timing_summary report. 

To calculate the Fmax, use the following equation:

Min Period = Actual Period - WNS

Fmax = 1/Min Period

WNS is the worst negative slack of the clock signal in the Intra-Clock Paths section.