AR# 57647

2013.3 Vivado - Inst Equation option in Schematic view does not show the INIT value for a LUT

Description

Turning on "Inst Equation" from the Schematic options in Vivado's Schematic view does not show the instance equation.

Solution

In Vivado 2013.3, the "Inst Equation" is actually running an "Update Schematic" command rather than showing the instance equation.

This issue will be corrected in Vivado Design Suite 2013.4.

To see the equation value, select the instance, then look at the Properties View panel.

AR# 57647
Date Created 09/26/2013
Last Updated 11/08/2013
Status Active
Type Known Issues
Tools
  • Vivado Design Suite - 2013.3