AR# 59127

LogiCORE IP Video Deinterlacer v2.00.a - The Pulldown 2:2 Field mode selection description is reversed


The Pulldown 2:2 Field mode selection description is reversed. This affects the Video Deinterlacer v2.00.a to v4.0 Product Guide PG017.


The Video Deinterlacer Product Guide (PG017) mode register bit 9 contains the selection option for the Pulldown 2:2 Field mode selection.

  • v2.00.a Product Guide (PG017), Table 2-11
  • v3.00.a Product Guide (PG017), Table 2-10
  • v4.0 Product Guide (PG017) under the Mode (0x0004) Register description

The correct description is:

  • Select which field precedence is used to detect 2:2 formats: when set '0' normal mode is used, when set '1' inverted mode is used.