AR# 59479

14.7 ISE Sysgen - Divider Block – Incorrect output when algorithm type is High_Radix

Description

Using the Divider Block in Sysgen 14.7 where input signals are all fixed value, the output signal changes frequently:

1.png

Solution

This is a known issue when the Algorithm type selected in the Divider block is High_Radix. 

The workaround is to change the Algorithm type to Radix2 from High_Radix as shown below:

 

3.png


This does not occur in Vivado Sysgen.










AR# 59479
Date Created 02/19/2014
Last Updated 10/09/2014
Status Active
Type General Article
Devices
  • Kintex-7
Tools
  • ISE Design Suite - 14.6
  • ISE Design Suite - 14.7
IP
  • Divider