AR# 60292

XADC Wizard v3.0 Rev 3 - Vivado 2014.1 - Release Notes and Known Issues

Description

These Release Notes are for the XADC Wizard v3.0 Rev 3, released in Vivado 2014.1 and contain the following information:

  • General Information
  • New Features
  • Bug Fixes
  • Known Issues

Solution

General Information

The XADC Wizard v3.0 Rev 3 supports the 7 series and Zynq devices. 

You can use the Wizard to customize the I/O Ports usage, the User Alarms and Thresholds, and the Channel Sequencer.

New Features in v3.0 Rev 3

None

Bug Fixes in in v3.0 Rev 3

Corrected GUI enablement option in the default sequencer mode.

Known Issues v3.0 Rev 3

XADC Wizard v3.0 core in 2014.1 with XSIM simulator always gives zeros on DRP read data when ENABLE_EXTERNAL_MUX mode is set to "true".

Workaround: Use QuestaSim when ENABLE_EXTERNAL_MUX is set to "true"

XADC Wizard v3.0 core in 2014.1 asserts TVALID incorrectly for temperature channels in Simultaneous Selection Mode when Temperature bus is selected.

Workaround: Use channel sequencer mode

Revision History
04/15/14 - Initial Release

AR# 60292
Date Created 04/15/2014
Last Updated 05/09/2014
Status Active
Type Release Notes
Devices
  • Artix-7
  • Kintex-7
  • Virtex-7
  • Zynq-7000
Tools
  • Vivado Design Suite - 2014.1