2014.1 Vivado Processing System 7 - "Validation failed for parameter 'PCW QSPI PERIPHERAL ENABLE" on import of XPS settings

Description

When importing a Processing System 7 export from XPS, the following error occurs. 

How do I resolve this issue?

Validation failed for parameter 'PCW QSPI PERIPHERAL ENABLE(PCW_QSPI_PERIPHERAL_ENABLE)' with value '1' for BD Cell '/processing_system7_0'.
QSPI MODE : Conflict from - and -
QSPI MODE : Conflict from - and -
QSPI MODE : Conflict from - and -
QSPI MODE : Conflict from - and -
qspi mutext : Conflict from - and - and -
qspi mutext : Conflict from - and - and -
qspi mutext : Conflict from - and - and -
qspi mutext : Conflict from - and - and -


Solution

In Vivado, only one QSPI mode can be selected among single, dual and parallel topologies.

The options are now mutually exclusive, leading to EDK XPS generated QSPI settings not working in Vivado.

To work around this issue, the XML file can be edited in a text editor under the following scenarios:

Single QSPI is enabled


No change is needed

Dual Stacked is enabled:


Add the following line in the XML
<set param="PCW::QSPI::GRP_SINGLE_SS::ENABLE" value="0" />

Dual Parallel is enabled:

Add the following lines in the xml
<set param="PCW::QSPI::GRP_SS1::ENABLE" value="0" /> 

<set param="PCW::QSPI::GRP_SINGLE_SS::ENABLE" value="0" />