AR #612 - 9.2i Timing Analyzer - Timing report displays an increase of items analyzed for my constraints

Search Answers Database


 

9.2i Timing Analyzer - Timing report displays an increase of items analyzed for my constraints

AR# 612
Part SW-Timing Analyzer/TRCE
Last Modified 2008-06-19 00:00:00.0
Status Active
Keywords increase, items, analyzed, paths, constraints, PERIOD

Description

Keywords: increase, items, analyzed, paths, constraints, PERIOD

When I review the items analyzed for my constraints, I notice the number of paths increased compared to 8.x analysis. What caused this?

Solution

A bug was found in the timing engine of the 8.x software that was fixed in the 9.x release. This bug caused some paths in the carry chain and input logic to be removed from analysis. This bug affected only Spartan-3 and Spartan-3e devices.

We recommend rerunning timing analysis with 9.x or 10.1 timing analyzer. If you are unable to migrate to 9.x or 10.1, you can add the following in your PCF:

For s3:
ENABLE = Tcinxb;
ENABLE = Tdiffin;
ENABLE = Tioftiq;

For s3e:
ENABLE = Tcinxb;
 
 
Jobs Events Webcasts News Investors Feedback Legal Privacy Trademarks Sitemap