AR# 61899

2014.3 Vivado Serial I/O Debug - IBERT - Error when upgrading from 2014.2 with a Rxrefclk of 640

Description

An error is displayed when I migrate my 2014.2 IBERT design with a rxrefclk selection of 640.

ERROR: [IP_Flow 19-3461] Value '640.000' is out of the range for parameter 'C Protocol Rxrefclk Frequency 1(C_PROTOCOL_RXREFCLK_FREQUENCY_1)' for IP 'my_ip' .
Valid values are - 100.000, 128.000, 160.000, 192.000, 193.939, 200.000, 240.000, 256.000, 290.909, 300.000, 320.000, 387.879, 400.000, 480.0

Solution

This error is due to 640 being out of spec, and timing not being met.

The 640 selection was removed in the 2014.3 release.