AR# 62142

2014.2 AXI Performance Monitor: Incorrect metrics reported when AXI events happen in close intervals


The AXI performance monitor does not give correct metrics when used in advanced mode.


This is a known issue. The AXI performance monitor reports incorrect metrics when used in advanced mode and AXI events happen in close intervals.

The gap between Awvlid and wvalid is less than 3 clock cycles. 

This is fixed in the 2014.3 release of Vivado Design Suite.

AR# 62142
Date Created 09/23/2014
Last Updated 11/09/2015
Status Active
Type Known Issues
  • Vivado Design Suite - 2014.2
  • AXI Performance Monitor