MIG 7 series - Is Dynamic ODT supported?


Version Found: MIG 7 Series v2.1
Version Resolved: See (Xilinx Answer 54025)
Does MIG 7 series support Dynamic ODT?

It is mentioned in UG586.

UG586 June 4, 2014 Table 1-92:  RTT_WR:

This is the dynamic ODT write termination used in multiple-RANK designs. For single-component designs, RTT_WR should be disabled.


MIG 7 series does not support Dynamic ODT.
The parameter should always be set to "OFF".
(Xilinx Answer 46082) describes a solution for Dynamic ODT support but it is only for "special use of Dynamic ODT supported by Micron". 

Revision History
09/24/2014 - Initial Release
Note: The "Version Found" column lists the version the problem was first discovered.
The problem also exists in earlier versions, but no specific testing has been performed to verify earlier versions.