AR# 62330

XAPP589 v2.2 - VCXO G1 / G2 Range is incorrect

Description

In version v2.2 and previous of the VCXO XAPP589, it states the following in table 5:

G1[4:0] Input Filter linear path gain: range 0 to F.
G2[4:0] Input Filter integrator path gain: range 0 to C.

Solution

The ranges listed are incorrect and should be:

G1[4:0] Input Filter linear path gain: range 0 to 12 h.
G2[4:0] Input Filter integrator path gain: range 0 to 14 h.

The condition G2>G1+2 should always be respected for stability.