AR# 62783

2014.4 - SDK - Performance Monitor Not working for my GP interface

Description

I have a simple Hardware System design in IP Integrator with the GP port connected to the AXI Performance Monitor and exported to SDK.

However, If I create a simple application using the API for the AXI Performance Monitor, I do not see any activity on the GP.

 

How can this be addressed?

Solution

There is a limitation on the AXI Performance Monitor used in SDK.

The SDK expects the HP ports to be connected to slots 0-3 on the AXI Performance Monitor, ACP on slot 4, and the GP on slots 5 - 7.
AR# 62783
Date Created 11/10/2014
Last Updated 11/24/2014
Status Active
Type General Article
Devices
  • Zynq-7000
Tools
  • Vivado Design Suite - 2014.3
  • Vivado Design Suite - 2014.4