AR# 63011

2014.4 Partial Reconfiguration - Application Exception error occurs when running update_design for two RMs at the same time


There are 2 RMs in a fully routed partial reconfiguration design. 

The below error occurs when I attempt to update 2 RMs to black box with the following command:

update_design -cell {u0_RM u1_RM}  -black_box

ERROR: [Common 17-70] Application Exception: Net u1_RM/XX/clk_sys has NULL ParentLH, netlist be corrupted.


This issue has been fixed in the 2015.1 release of Vivado.

As a work-around in 2014.4, you can update the RMs to black box one by one:

update_design -black_box -cell [get_cells {u0_RM }]

update_design -black_box -cell [get_cells {u1_RM }]