AR# 63117

Vivado 2014.4, Zynq-7000 AP SoC - SBG packages frequencies incorrectly limited in Processing System 7 GUI


For Zynq devices in SBG packages, the Processing System 7 configuration GUI limits the maximum CPU frequency to 767MHz instead of 800MHz for -2, and to 867MHz instead of 1000MHz for -3.

How do I use the maximum frequency?


A software patch for Vivado 2014.4 is available which requires a Vivado file to be overwritten (unlike the normal Vivado patch flow with MYVIVADO).

See the readme file in the attached zip file for more information.

This issue will be fixed starting in Vivado Design Suite 2015.1.