AR# 63943

Vivado 2014.4 Implementation - Incremental Placer fails in Phase 7 Detail Placement


The following error is being received during Placement:

Phase 7 Detail Placement | Checksum: 1aafe0b0f

Time (s): cpu = 00:57:56 ; elapsed = 00:32:29 . Memory (MB): peak = 14778.527 ; gain = 3049.223 ; free physical = 52404 ; free virtual = 123467
ERROR: [Place 30-99] Placer failed with error: 'Detail Placement failed please check previous errors for details.'
Please review all ERROR, CRITICAL WARNING, and WARNING messages during placement to understand the cause for failure.
Ending Incremental Placer Task | Checksum: 127483e99


To work around this error in Vivado 2015.1, set the following parameter:

set_param place.useOldV7Cluster 1