AR# 63971

2015.1 Vivado Simulator - ERROR: [VRFC 10-1466] type time does not match with the integer literal

Description

With the following time type parameter defined:
 

parameter time TC = 9; 

Vivado Simulator returns an error in the compilation step:

ERROR: [VRFC 10-1466] type time does not match with the integer literal

Solution

This is a known issue with the Verilog Compiler of Vivado Simulator.

It is scheduled to be fixed in a future release.

To work around this issue, do not use a time type parameter.
AR# 63971
Date Created 03/20/2015
Last Updated 04/30/2015
Status Active
Type Known Issues
Tools
  • Vivado Design Suite - 2015.1