2014.4.4 - Vivado UltraScale Partial Reconfiguration - Can I persist the config port when SYSMON is used in reconfigurable module


When SYSMON (AMS tile) is used in reconfigurable module, can I persist the config port by setting the BITSTREAM.CONFIG.PERSIST property?


When SYSMON (AMS tile) is used in reconfigurable module, the BITSTREAM.CONFIG.PERSIST property can only be set to "NO".

If this violation is detected, the following DRC HDPR-52 will be reported:

ERROR: [Drc 23-20] Rule violation (HDPR-52) The persistent config port, controlled by BITSTREAM.CONFIG.PERSIST, is not supported when primitive cell '<NETLIST_ELEMENT>' is being reconfigured.