2015.2 UltraScale Partial Reconfiguration - No DRC message is reported if user places configuration(IO) Bank in PR region when Persist property is set

Description

When the BITSTREAM.CONFIG.PERSIST property is set, the configuration(IO) Banks cannot be included in a PR region.

However, there is no DRC reported to prevent the user from placing configuration(IO) Banks in PR regions that have the persist property set.

Solution

In Vivado 2015.3, the DRC HDPR-67 will be reported when the above issue is found.

Example error message during place_design:

ERROR: [DRC HDPR-67] Persistent configuration port restrictions in PR regions.: The BITSTREAM.CONFIG.PERSIST property is not supported when configuration bank '65' is inside the HD.RECONFIGURABLE Pblock 'pblock_RM".