AR# 65395

QDRIV IP - "UNKNOWN STATE ERROR" messages reported during simulations when using QuestaSim

Description

Version Found: QDRIV v1.0

Version Resolved: See (Xilinx Answer 58435)

When simulating the QDRIV IP using QuestaSim the following messages might be seen:

# tg_instr_sm_ps: UNKNOWN STATE ERROR - STATE HEX=x
#
# tg_instr_sm_ps: UNKNOWN STATE ERROR - STATE HEX=x
#
# Calibration Status is 00000000
# Current time is 108ns
# tg_instr_sm_ps: UNKNOWN STATE ERROR - STATE HEX=x
#
# tg_instr_sm_ps: UNKNOWN STATE ERROR - STATE HEX=x
#
# TEST PASSED

Solution

These messages are safe to ignore and will not affect functionality of the QDRIV IP in simulation or in hardware.


Revision History:

09/30/2015 - Initial Release