AR# 67071

Zynq UltraScale+ System Management Wizard 2016.1: Critical Warning because SYSMON reset is no longer a timing endpoint in some devices.

Description

During synthesis of the System Management Wizard IP, the RESET pin is not a valid timing endpoint.

In some cases this can lead to the following critical warning being seen:


CRITICAL WARNING: [Constraints 18-512] set_false_path: list of objects specified for '-to' option contains no valid endpoints

Solution

During synthesis of the System Management Wizard IP, the RESET pin is not a valid timing endpoint.

In some cases this can lead to the following critical warning being seen.

CRITICAL WARNING: [Constraints 18-512] set_false_path: list of objects specified for '-to' option contains no valid endpoints

There is a constraint in the IP that sets this false path but the endpoint is not found.

This will be fixed in an upcoming release of the IP.

As a work-around, the set_false_path constraint on the RESET pin in the IP can be removed.

AR# 67071
Date Created 04/20/2016
Last Updated 05/25/2016
Status Active
Type General Article
Devices
  • Zynq UltraScale+ MPSoC
  • Kintex UltraScale+
  • Virtex UltraScale+
Tools
  • Vivado Design Suite
IP
  • System Monitor Wizard