UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

Page Bookmarked

AR# 11109

Schematic - "ERROR:SchematicEditor - Net "" Some nets have similar names ..."

Description

The following error message occurs during an ECS error check:

"ERROR:SchematicEditor - Net "<bus_name>" Some nets have similar names which make this name illegal. For example, a net named "A" would make a name like A(0:3) illegal."

Solution

This error is issued for two bus segments that have the same name but different indexes (i.e., mybus(0:3) and mybus(4:7)).

To fix the problem, add a full version of that bus to the sheet. For the example above, create a bus named "mybus(0:7)." It is not necessary to connect the new complete bus to any components.

AR# 11109
Date 12/15/2012
Status Archive
Type General Article