AR# 13065

4.1i ISE - A system error occurs when I call up ModelSim XE 5.3d from Project Navigator

Description

Keywords: ISE, 4.1i, ModelSim XE, Post, Route, Simulation, System Error, out of memory

Urgency: Standard

General Description:
When I call up ModelSim XE from the Project Navigator of ISE 4.1i with Service Pack 2 to run the post-route simulation, the following error is reported:

"System Error [19] - Out of memory: failed to create new token during parse for [0][NIwInvertersugnal_SPI_LINK_RECEIVER_INST_C546_AN1_IN1]"

When I click "OK" in the error message window, a second error appears:

"System Error [38] - Memory deallocation failure:
object_count=1 total_memory = 80
TOKEN_LIST_TYPE = 80
VARIABLE_LIST_TYPE=1232"

Solution

(NOTE: This is a post-route simulation problem only. When ModelSim XE is called up for a functional simulation of the design, no errors occur.)

ModelSim will perform post-route simulation correctly when it is run stand-alone mode.

This problem was fixed in the 4.2i ISE software.
AR# 13065
Date 08/11/2003
Status Archive
Type General Article