AR# 15976

Project Navigator - Processes that run for a project on a network drive are not updated

Description

I create a project on a remote drive and the initial process run is successful. However, if I change a process option, successive process runs do not result in the process status marker being updated to Tick. A question mark remains, indicating that the process is out-of-date.

Solution


This issue is caused by a difference between the system clocks in the local and remote (file server) computers. When you write a file to a network drive, the time stamp is based on the file system computer. If the file server is ahead of the local computer, any generated files might acquire a time stamp before the source files; in this case, Project Navigator detects this and marks the file or a process, depending on the file, as "out-of-date".
The best solution to this problem is to ensure that the two system clocks are synchronized.
AR# 15976
Date Created 09/03/2007
Last Updated 12/15/2012
Status Active
Type General Article