AR# 19724

6.3i SimPrim, Timing Simulation - Compilation of X_IDELAYCTRL causes an "Instance <instance_name> does not have a generic named 'tpd_rst_rdy'" error (VHDL, SDF)

Description

Keywords: SimPrim, VHDL, timing, simulation, ModelSim, NC-VHDL, generic, tpd_rst_rdy, X_IDELAYCTRL, Virtex-4, SDF

Urgency: Standard

General Description:
When I run a timing simulation of a design with IDELAYCTRL, the following error occurs:

"** Error <sdf_file_name>(<line_no>): Instance '<instance_name>' does not have a generic named 'tpd_rst_rdy'."

Many more similar errors appear.

Solution

This problem has been fixed in the latest 6.3i Service Pack available at:
http://support.xilinx.com/xlnx/xil_sw_updates_home.jsp
The first service pack containing the fix is 6.3i Service Pack 1.
AR# 19724
Date Created 09/03/2007
Last Updated 11/18/2008
Status Archive