LogiCORE SPI-3 LINK Layer Core v4.0 - Bitgen gives ERROR:PhysDesignRules:755 - IOB comp <TX_DTPA(16)> at location <AH34> is VCCO (also applies to SPI-3 PHY Layer)

Description

General Description:

When running design with SPI-3, you might receive the following Bitgen error:

ERROR:PhysDesignRules:755 - IOB comp <TX_DTPA(16)> at location <AH34> is VCCO

incompatible for bank <11>. The VCCO established for this bank is <3.300000>.

ERROR:PhysDesignRules:755 - IOB comp <DTPA(19)> at location <AG32> is VCCO

incompatible for bank <11>. The VCCO established for this bank is <3.300000>.

ERROR:PhysDesignRules:755 - IOB comp <DTPA(27)> at location <AH33> is VCCO

incompatible for bank <11>. The VCCO established for this bank is <3.300000>.

ERROR:PhysDesignRules:755 - IOB comp <DTPA(28)> at location <AK32> is VCCO

incompatible for bank <11>. The VCCO established for this bank is <3.300000>.

ERROR:PhysDesignRules:755 - IOB comp <DTPA(29)> at location <AK31> is VCCO

incompatible for bank <11>. The VCCO established for this bank is <3.300000>.

ERROR:PhysDesignRules:755 - IOB comp <TX_DTPA(27)> at location <AL5> is VCCO

incompatible for bank <8>. The VCCO established for this bank is <3.300000>.

ERROR:PhysDesignRules:755 - IOB comp <TX_DTPA(28)> at location <AF18> is VCCO

incompatible for bank <4>. The VCCO established for this bank is <3.300000>.

ERROR:PhysDesignRules:755 - IOB comp <RVAL> at location <AF16> is VCCO

incompatible for bank <4>. The VCCO established for this bank is <3.300000>.

ERROR:PhysDesignRules:755 - IOB comp <STPA> at location <AD34> is VCCO

incompatible for bank <11>. The VCCO established for this bank is <3.300000>.

ERROR:PhysDesignRules:755 - IOB comp <RSOP> at location <AF15> is VCCO

incompatible for bank <2>. The VCCO established for this bank is <2.500000>.

ERROR:PhysDesignRules:755 - IOB comp <TSOP> at location <AK11> is VCCO

incompatible for bank <8>. The VCCO established for this bank is <3.300000>.

ERROR:PhysDesignRules:755 - IOB comp <TX_SRC_RDY> at location <AG15> is VCCO

incompatible for bank <2>. The VCCO established for this bank is <2.500000>.

ERROR:PhysDesignRules:755 - IOB comp <RX_ERR> at location <AJ22> is VCCO

incompatible for bank <2>. The VCCO established for this bank is <2.500000>.

Solution

This occurs for both SPI PHY and SPI Link using ISE7.1i. It occurs for VCCO = 3.3V and 2.5V both in the same design.

This error does not occur using ISE8.1i.