UPGRADE YOUR BROWSER
We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!
When EDK uses DCM in a Virtex-4 system, the following warning occurs at simulation.
"# ** Warning: Attribute Syntax Warning The attribute FACTORY_JF on DCM_ADV instance * is set to 1100000010000000.
# Legal Values for this attribute is F0F0 hex
# Time: 0 ps Iteration: 0 Instance: /system/dcm_0/dcm_0/using_dcm_adv/dcm_adv_inst"
You can safely ignore this warning. EDK sets the DCM attribute "FACTORY_JF" to "C080"; however, BitGen sets the attribute to the correct value "F0F0."
This problem has been fixed in the latest EDK 9.1i Service Pack, available at:
http://www.xilinx.com/xlnx/xil_sw_updates_home.jsp
The first service pack containing the fix is EDK 9.1i Service Pack 2.
AR# 25042 | |
---|---|
Date | 05/21/2014 |
Status | Archive |
Type | General Article |